Gipfel Engineering

VMS-1180 Vertical Multi-Stage Pump

The VMS-1180 is a vertical multi-stage centrifugal pump engineered for high-head water transfer where compact installation, stable hydraulic performance, and continuous-duty operation are required. Its stacked impeller-and-diffuser stage arrangement develops higher discharge pressure than a single-stage centrifugal pump while maintaining a narrow vertical footprint suitable for borewell, sump, tank, and pressure-boosting installations. Vertical multi-stage pumps are commonly used in water supply, pressure boosting, boiler-feed, cooling-water, irrigation, dewatering, washing, and fire-fighting services.

For submersible-type applications, the pump is suitable for clean or slightly contaminated water duties such as groundwater extraction, domestic and drinking-water supply, general irrigation, pressure boosting, groundwater lowering, fire-fighting support, cooling circuits, and industrial or municipal water transfer.

Key Features

  • Multi-stage high-head hydraulic design for pressure boosting and deep-well lifting duties.
  • Integrated intake screening to reduce ingress of coarse suspended particles at the pump inlet.
  • Low-vibration vertical assembly for stable operation in borewell, tank, and sump installations.
  • Vertical submersible configuration minimizes floor-space requirement and enables submerged operation.
  • Continuous-duty electric motor compatibility for municipal, agricultural, and industrial operating cycles.
  • Corrosion-resistant wetted construction with stainless-steel hydraulic components for clean-water reliability.
  • Application flexibility for groundwater, irrigation, building services, cooling water, washdown, and utility transfer.

Service Overview

Parameter Value
Equipment Vertical multi-stage submersible centrifugal pump
Fluid Clean water, raw water, potable water, groundwater, slightly contaminated water
Service Nature High-head lifting, pressure boosting, transfer, circulation, and dewatering
Operating Mode Continuous or intermittent duty with motor protection and dry-run safeguards recommended

Specifications & Operating Limits

Parameter Min Max Notes
Size 100 mm (4.000”) bore class — Discharge size on request
Pressure / Head — 25 bar (363 psi) / 305 m (1,000 ft) head Depends on stage count
Temperature 0 °C (+32 °F) +50 °C (+122 °F) Clean-water submersible service
Speed — 2900 rpm 50 Hz, 2-pole motor
Note: Limits are maximum values for individual parameters and are not simultaneous. The duty point, materials and motor are selected for each application; contact Gipfel Engineering to confirm suitability for your duty.

Materials of Construction

Component Standard Options Notes
Pump Casing / Outer Shell Stainless Steel SS 304 SS 316 / Duplex SS Selection depends on the chloride level and water chemistry
Impellers & Diffusers Stainless Steel SS 304 SS 316 / Engineered Polymer Multi-stage pressure generation components
Shaft & Coupling SS 304 / SS 316 Duplex SS Requires corrosion and torsional-load verification
Mechanical Seal / Wear Parts Carbon / Ceramic / NBR SiC / TC / FKM / EPDM Material pairing depends on water quality and temperature
Motor Housing Stainless Steel / Cast Iron with coating Full SS 316 For borewell, sump, or tank-mounted submersible duty

Applications

  • Domestic, commercial, and municipal water supply.
  • Construction dewatering and groundwater lowering.
  • Agricultural irrigation and spray irrigation systems.
  • Groundwater extraction from borewells and deep wells.
  • Fire-fighting support systems and sprinkler water supply.
  • Cooling-water circulation and HVAC make-up water service.
  • Washdown systems, fountains, and general clean-water transfer.
  • Raw-water transfer for treatment plants and industrial utilities.
  • Pressure boosting for buildings, distribution lines, and utility networks.

Frequently Asked Questions

  1. What is the VMS-1180?
    The VMS-1180 is a vertical multi-stage centrifugal pump engineered for high-head water transfer where compact installation, stable hydraulic performance, and continuous-duty operation are required.
  2. What are the operating limits?
    Size from the 100 mm (4.000”) bore class; pressure up to 25 bar (363 psi), up to 305 m (1,000 ft) head depending on stage count; temperature 0 °C to +50 °C (+32 °F to +122 °F); speed up to 2900 rpm. The final selection is made to the duty point, and these limits are not simultaneous.
  3. Which materials are used in the VMS-1180?
    Pump Casing / Outer Shell: Stainless Steel SS 304; Impellers & Diffusers: Stainless Steel SS 304; Shaft & Coupling: SS 304 / SS 316. Options are listed in the materials table.
  4. Which shaft sealing is used?
    Carbon / Ceramic / NBR as standard, with SiC / TC / FKM / EPDM as options.
  5. Which fluids can the VMS-1180 handle?
    Clean water, raw water, potable water, groundwater, slightly contaminated water.
  6. Where is the VMS-1180 used?
    Agricultural irrigation and spray irrigation systems; Domestic, commercial, and municipal water supply; Construction dewatering and groundwater lowering; Groundwater extraction from borewells and deep wells; Fire-fighting support systems and sprinkler water supply.