Description
The SPT-1160 Split Casing Pump is a heavy-duty centrifugal pump concept designed for high-flow, continuous-duty liquid transfer where efficiency, service accessibility, and mechanical stability are critical. The horizontally split casing arrangement allows the upper casing half to be removed for internal inspection and maintenance without disturbing major pipework, while double-suction hydraulic geometry is commonly used in split-case designs to reduce axial thrust and improve bearing and seal life. Split-case pump manufacturers commonly position this design for water supply, HVAC, district cooling, irrigation, and industrial utility duties.
For target applications, the SPT-1160 should be positioned for municipal water distribution, chilled/condenser water circulation, fire-fighting systems, irrigation pumping stations, power-plant service water, petrochemical utility water, cooling-water recirculation, and general industrial transfer. Comparable split-case pump ranges are used for public water supply, air-conditioning/heating systems, district heating/cooling, irrigation, fire-fighting, power stations, shipbuilding, petrochemical service, and clean/service-water handling.
Technical Key Features
- Rigid bearing support arrangement for stable shaft operation under sustained industrial duty.
- Double-suction impeller configuration reduces axial hydraulic load and supports smoother operation.
- Renewable wear components, such as wear rings and shaft sleeves, support long-term maintainability.
- Service-friendly construction enables internal access without full pump removal from the piping system.
- High-flow centrifugal hydraulic layout suitable for continuous water transfer and utility circulation duties.
- Horizontally split casing design for rapid inspection of impeller, wear rings, shaft sleeves, and sealing area.
- Multiple sealing options, including gland packing, component mechanical seal, or cartridge mechanical seal.
Service Overview
| Parameter | Value |
| Equipment | Horizontal split casing centrifugal pump |
| Fluid | Clean water, raw water, treated water, chilled water, condenser water, service water, cooling water |
| Service Nature | High-flow, low-to-medium head, continuous utility and transfer service |
| Operating Mode | Continuous / standby / duty-assist operation in pump stations, HVAC plants, and industrial utilities |
Specifications
| Item | Min | Max | Typical / Notes |
| Size | 80 mm (3.000”) | 1200 mm (48.000”) | Project-specific nozzle and impeller selection; exact SPT-1160 frame to be verified |
| Pressure | Atmospheric suction | 25 bar (363 psi) | Typical split-case range; higher pressure executions may be available on request |
| Temp | -30°C (-22°F) | +120°C (+248°F) | For clean-water and HVAC duties; up to +140°C (+284°F) possible with suitable materials/sealing |
| Speed | 740 RPM | 3000 RPM | Based on motor frequency, pump size, and hydraulic duty point |
Published split-case pump ranges show maximum working pressures around 25–30 bar (363–435 psi) and fluid temperatures up to 120–140°C (248–284°F), depending on design and material execution.
Materials
| Component | Standard Material | Optional Material | Comment |
| Casing | Cast Iron / Ductile Iron | Cast Steel, SS 304, SS 316, Duplex SS | Select based on pressure, corrosion, and water chemistry |
| Impeller | Bronze / Cast Iron | SS 304, SS 316, Duplex SS | Double-suction impeller preferred for axial thrust balance |
| Shaft | SS 410 / SS 420 | SS 304, SS 316, Duplex SS | Shaft material to match corrosion and strength requirements |
| Wear Rings | Bronze / Stainless Steel | Duplex SS / Hardened SS | Renewable design recommended for lifecycle efficiency |
| Shaft Sealing | Gland Packing | Mechanical Seal / Cartridge Seal | Mechanical seal recommended for leakage-controlled service |
| Bearings | Anti-friction Bearings | Heavy-duty grease/oil lubricated arrangement | Selection depends on duty, speed, and bearing-life requirement |
Applications
- District cooling and district heating plants.
- Industrial cooling-water and service-water transfer.
- Irrigation, drainage, and raw-water intake pumping.
- Municipal water supply and distribution pumping stations.
- Power plant utility water, cooling water, and auxiliary circulation.
- Petrochemical, refinery, fertilizer, paper, sugar, and textile plant utilities.
- HVAC chilled-water, condenser-water, and hot-water circulation systems.
- Fire-fighting pump systems for sprinkler, hydrant, and standpipe networks.
Operating Limits
| Parameter | Value |
| Pressure | Up to 25 bar (363 psi), higher on request after casing/flange review |
| Temp | -30°C to +120°C (-22°F to +248°F); special execution up to +140°C (+284°F) |
| Speed | Up to 3000 RPM typical for 50 Hz duty; verify by pump curve and impeller diameter |
| Size Range | 80 mm to 1200 mm (3.000” to 48.000”), duty-point specific |
Engineering note
Exact SPT-1160 capacity, head, NPSH, efficiency, flange rating, and motor power were not available from a public model-specific source during the search. The values above are industry-standard split-case pump assumptions and should be verified against the final pump curve, GA drawing, material specification, and selected sealing arrangement before release.