Cryogenic liquids such as liquid nitrogen (−196 °C), LNG (−162 °C) and ethylene (−104 °C), and refrigerated ammonia (−33 °C), sit close to their boiling point. Elastomers become glass-hard below their glass transition, moisture freezes on the atmospheric side, and any heat input flashes the face film. Gipfel has supplied seals for liquid nitrogen duty. For plant-level selection see Liquid Nitrogen & Cryogenic and Ammonia Refrigeration.
Key Sealing Challenges
- Elastomer embrittlement: O-rings lose sealing below their glass-transition temperature; cryogenic seals use welded metal bellows (Inconel 718) with PTFE or graphite static seals.
- Icing: atmospheric moisture freezes on the gland and faces; an API Plan 62 dry-nitrogen purge keeps the atmospheric side dry.
- Flashing: heat from face friction vaporises the film; balanced faces and SiC vs cryogenic carbon pairs keep heat low.
- Containment: volatile flammable cryogens (LNG, ethylene) use a containment seal with Plan 72 buffer gas and Plan 76 vent to flare.
- Ammonia compatibility: ammonia attacks copper alloys and FKM; EPDM or suitable grades and copper-free materials are used.
Which mechanical seal is used on liquid nitrogen pumps?
A metal bellows seal with Inconel 718 welded bellows, SiC vs cryogenic carbon faces and no elastomers (PTFE or graphite static seals) is used, with an API Plan 62 dry-nitrogen purge on the atmospheric side to prevent icing.
Root-Cause Failure Analysis — Field Example
Symptom: LN2 pump seal leaks after a cool-down; ice ball on the gland.
├── Incorrect Response: "Fit a harder O-ring."
├── Diagnostic Evidence Required:
│ ├── Are elastomer O-rings used below their glass-transition temperature?
│ ├── Is a dry-nitrogen purge fitted and flowing?
│ └── Was the pump cooled down slowly as specified?
└── Engineered Solution:
├── Inconel 718 welded metal bellows seal, elastomer-free.
├── SiC vs cryogenic carbon faces.
└── Plan 62 dry-nitrogen purge; controlled cool-down.
Frequently Asked Questions
Why are O-rings avoided in cryogenic seals?
Below their glass-transition temperature, elastomers become rigid and stop sealing. Welded metal bellows provide the flexibility instead, with PTFE or graphite for static joints.
Why is a dry-nitrogen purge used on cryogenic seals?
The atmospheric side of a cryogenic seal runs far below the dew point of the surrounding air, so moisture freezes on the gland and faces. An API Plan 62 dry-nitrogen purge keeps this area dry and free of ice. Note: Gipfel does not offer seals for liquid oxygen service. Related: Liquid Nitrogen · Ammonia Refrigeration · Hydrocarbons · Cryogenic Mechanical Seal.
Request a Seal Selection
Send the fluid name and concentration, SDS, temperature, suction and discharge pressure, pump make and model, shaft size and speed to info@gipfelengg.com or use our enquiry form. Gipfel Engineering (ISO 9001:2015, NSIC-registered MSME, Mumbai) designs and manufactures mechanical seals, seal support systems and process pumps.
Equipment solutions: Vertical Can Pumps · Overhung Pumps · Compressors.
Pump Duty & Mechanical Seal Selection Matrix
Typical values for selection guidance only. Final selection is made against the customer duty sheet and the fluid SDS.
| Pump duty | Fluid | Typical temp. | Typical pressure (bar) | Seal arrangement | Faces / elastomer | API piping plan |
|---|---|---|---|---|---|---|
| Liquid Nitrogen Pump | LN₂ | −196 °C | 3–15 bar | Cryogenic metal bellows seal | SiC vs cryogenic carbon / PTFE or graphite; Inconel 718 bellows | API Plan 62 dry N₂ purge |
| LNG Transfer Pump | LNG | −162 °C | 5–20 bar | Cryogenic metal bellows seal with containment seal | SiC vs cryogenic carbon / PTFE; Inconel 718 bellows | API Plan 72 + Plan 76 + Plan 62 |
| Ethylene Pump | Liquid ethylene | −104 °C | 10–30 bar | Cryogenic metal bellows seal with containment seal | SiC vs carbon / PTFE | API Plan 72 + Plan 76 |
| Ammonia Pump | NH₃ refrigerant | −33 to 0 °C | 3–15 bar | Balanced multi-spring cartridge | SiC vs carbon / EPDM; copper-free | API Plan 11 + Plan 62 |
Reviewed by Gipfel Engineering’s technical team.
Technical Information Disclaimer
The information on this page, including process descriptions, flow diagrams, operating ranges, seal arrangements, materials and piping plans, is general technical guidance for information only. Values shown are typical industry ranges, not guaranteed ratings or specifications of any Gipfel Engineering product. Each application differs. Seal selection, material compatibility, installation and operation must be verified by qualified personnel against the specific equipment data sheet, process conditions, applicable codes and the pump manufacturer’s instructions. A binding recommendation is given only in a written quotation or technical offer from Gipfel Engineering.
References to standards (such as API 682, ISO 21049, ISO 3069, FDA 21 CFR 177.2600 and NACE MR0175 / ISO 15156) describe common industry practice. They do not mean that any product is certified, qualified or approved to that standard unless this is confirmed in writing for a specific order. Third-party company and product names, including “equivalent to” references, are used for identification only and remain the trademarks of their owners. No affiliation, endorsement or OEM approval is implied.
Compliance with safety, hazardous-area, environmental and statutory requirements at the user’s site remains the responsibility of the plant owner or operator. To the extent permitted by law, Gipfel Engineering accepts no liability for loss or damage arising from reliance on this general information without a confirmed written recommendation. Content may change without notice.